Von Duprin 98/99 Installation Overview
The Von Duprin 98/99 series exit devices are renowned for their durability and reliability. This guide provides a comprehensive overview of the installation process. It also covers essential considerations for optimal performance, aiming for a smooth and secure setup.
General Installation Considerations
Before commencing the installation of your Von Duprin 98/99 series exit device, several key factors must be considered. First, ensure you have the correct model and trim for your specific door type and application. Verify the door’s dimensions and material to guarantee compatibility with the chosen device. Gather all necessary tools, including measuring tapes, drills, screwdrivers, and cutting equipment. Always refer to the manufacturer’s instructions and local building codes for compliance. Prioritize safety by wearing appropriate protective gear, such as safety glasses and gloves. A clean and well-lit workspace will further contribute to a successful installation;
Preparing the Door for Installation
Proper door preparation is crucial for a successful Von Duprin 98/99 series exit device installation. This involves assessing the door’s integrity, taking accurate measurements, and marking the necessary cutouts for the device.
Door Preparation and Measurements
Before installing your Von Duprin 98/99 series exit device, meticulous door preparation and accurate measurements are paramount. First, assess the door’s material (wood or metal). Inspect for any damage or irregularities. Next, consult the device’s installation template to mark the precise locations for drilling pilot holes, creating cutouts for the chassis, and the strike plate. Ensure accurate measurements to guarantee proper alignment. This includes door thickness, width, and the distance from the floor. Correctly preparing your door ensures that the exit device functions flawlessly and contributes to the overall security of the opening.
Cutting the Device to Proper Length
Adjusting the device length is crucial for optimal fit. This section details how to accurately cut the Von Duprin 98/99 to match your door’s width, ensuring proper functionality.
Cutting Instructions for Optimal Fit
To achieve the best fit and performance from your Von Duprin 98/99 series exit device, precise cutting is essential. Begin by accurately measuring the door width where the device will be installed. Subtract the necessary amount from the end opposite the cylinder hole, referencing the device installation instructions for specific measurements. Using appropriate cutting tools, carefully trim the device to the determined length. Ensure a clean, straight cut to prevent any operational issues. After cutting, deburr any sharp edges to ensure smooth operation and prevent injury. A correctly sized device guarantees proper latching and security.
Installing the Bottom Adjusting Screw
Proper adjustment of the bottom rod is crucial for smooth operation. Secure the bottom adjusting screw through the bottom rod, ensuring the latch bolt clears the floor.
Procedure for Bottom Rod Adjustment
Begin by retracting the top latch bolt completely. Next, carefully position the bottom rod to ensure the latch bolt has adequate clearance from the floor. Insert the bottom adjusting screw through the bottom rod, securing it in place. While the top latch bolt remains retracted, meticulously adjust the bottom rod’s position until the bottom latch bolt moves freely without obstruction. Ensure smooth operation and proper engagement. Verify the bottom latch bolt clears any flooring or thresholds, guaranteeing reliable functionality. Tighten the adjusting screw, maintaining the correct position. This step is critical for optimal device performance.
Trim Installation Considerations
Proper trim installation is critical for the exit device’s functionality. Consider the trim type, like BE, ensuring compatibility. Also, it’s important to follow specific guidelines and address any unique requirements, ensuring a secure fit.
BE Trim Installation (e.g., 996L-BE)
When installing BE trim, such as the 996L-BE model, ensure the trim lock tumbler on the back of the device is in the UP position before proceeding. This is a crucial step to guarantee proper functionality. Failing to correctly position the tumbler may lead to operational issues. Always double-check the alignment. Also, be sure to consult the specific trim installation instructions for detailed guidance. Proper engagement with the exit device mechanism is essential for smooth operation, and a secure installation is paramount for the intended purpose of the exit hardware.
Using Digital Interactive Instructions
For an enhanced installation experience, access our smartphone-friendly digital interactive instructions. Simply scan the QR code provided to gain access to detailed step-by-step guidance. This ensures a smooth, correct installation process.
QR Code Access for Installation Guides
To simplify the installation process for Von Duprin 98/99 series exit devices, we provide digital interactive instructions accessible via QR codes. These codes are strategically placed on the product packaging and within documentation. Scanning the QR code with a smartphone or tablet instantly directs you to a comprehensive, user-friendly online guide. This digital resource includes detailed steps, diagrams, and videos, ensuring accurate and efficient installation. This innovative approach minimizes errors, saves time, and provides a superior installation experience compared to traditional paper manuals, ensuring your device functions flawlessly.
Specific Instructions for Rim Exit Device
Installing the Von Duprin 98/99 rim exit device requires specific steps. This section details those steps. Precise alignment and secure mounting are crucial for reliable operation and safety.
Von Duprin 98/99 Rim Exit Device Installation
The Von Duprin 98/99 rim exit device installation involves precise measurements and careful alignment. Begin by marking the door according to the provided template. Then, securely mount the chassis and latch assembly. Ensure the strike plate is properly positioned on the frame to guarantee smooth latching and unlatching. Pay close attention to the cylinder installation if applicable, making sure it operates freely. Finally, test the device thoroughly to confirm proper functionality before completing the installation. Refer to the video guides for visual aid and enhanced understanding of each step.
Surface Vertical Rod Exit Device Installation
Installing a surface vertical rod exit device requires careful attention to alignment and adjustments. Ensure the rods are properly cut and that the latches engage smoothly for optimal security.
98/9927 Installation Details
The 98/9927 surface vertical rod exit device requires precise installation for reliable operation. This includes careful measurements and proper alignment of the rods. Refer to specific instructions for NL, EO, DT trims, and double cylinder devices like TP-2, L-2, and K. Ensure the top and bottom latches engage correctly with the frame. Adjustments may be necessary to achieve smooth and secure locking. Use appropriate fasteners for the door material. Following these details ensures the device meets safety and security standards, providing reliable exit functionality when needed in emergency situations.
Remote Undogging (RU) and Remote Monitoring (RM) Kits
Remote Undogging (RU) and Remote Monitoring (RM) kits enhance the functionality of Von Duprin 98/99 series exit devices. These kits allow for remote control and monitoring of the door’s security status.
Retrofit Kit Installation for 98/99 Series
Installing the Remote Undogging (RU) and Remote Monitoring (RM) retrofit kits on your existing Von Duprin 98/99 series exit devices is a straightforward process. These kits are also compatible with 33A/35A series devices, offering versatility. Begin by carefully reviewing the device installation instructions included with the kit. The process involves cutting the device or cover plate to the proper length, typically on the end opposite the cylinder hole. Remember to consult the device installation instructions for detailed information specific to your setup. These kits significantly improve security and access control capabilities.
Adjusting the Latch Bolt
Proper adjustment of the latch bolt is crucial for the reliable operation of your Von Duprin 98/99 series exit device. Fine-tuning ensures a secure and consistent latching action, enhancing overall security.
Ensuring Proper Latch Bolt Clearance
To guarantee the smooth functioning of your Von Duprin 98/99 series exit device, ensuring proper latch bolt clearance is paramount. Insufficient clearance can lead to binding, preventing the door from latching correctly. Conversely, excessive clearance might compromise security, rendering the latch less effective.
The goal is to achieve a balance, permitting the latch bolt to engage fully with the strike plate without obstruction. Careful measurement and adjustment are essential steps. This ensures the door closes securely and the exit device functions as intended, providing reliable egress during emergencies and maintaining security against unauthorized entry.